Description
1, Product Introduction
High-precision laboratory conductivity meter, suitable for measuring conductivity, TDS, salinity, resistivity and conductivity ash, 1 to 3 points calibration, accuracy: 0.5% F.S.
2, Features
• High-precision laboratory conductivity meter is equipped with a 7 inch TFT display.
• 1 to 3 points calibration with automatic recognition for conductivity standards.
• Selectable conductivity ash, cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS conversion factor, linear/non-linear/pure water compensations,percentage/seawater/practical salinity measurement modes.
• Automatic temperature compensation corrects conductivity measurements to the reference temperature.
• Auto-read function senses and locks the measurement endpoint.
• Timed interval readings send the measurement data to a PC or printer.
• Limit Alarm automatically alerts when reading exceeds the specified range.
• Calibration due alarm reminds the user to calibrate the meter regularly.
• Calibration log shows the date, time, calibration point and factor.
• Password protection prevents the unauthorized calibration and settings.
• Expanded memory stores or recalls up to 1000 data sets.
• Reset function automatically resumes all settings back to the factory defaults.
3, Specification
Model |
|
A150-DL |
Conductivity |
|
|
Range |
|
0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm |
Resolution |
|
0.001, 0.01, 0.1, 1, automatic |
Accuracy |
|
±0.5% F.S. |
Calibration |
|
1 to 3 points |
Calibration Solutions |
|
10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS |
TDS |
|
|
Range |
|
0 to 10.00, 100.0, 1000 mg/L, 10.00, 200.0 g/L |
Resolution |
|
0.01, 0.1, 1, automatic |
Accuracy |
|
±1% F.S. |
TDS Conversion Factor |
|
0.1 to 1.0 (default 0.5) |
Salinity |
|
|
Range |
|
0.00 to 80.00 ppt / 0.00 to 42.00 psu / 0.00 to 8.00% |
Resolution |
|
0.01 |
Accuracy |
|
±1% F.S. |
Resistivity |
|
|
Range |
|
0.00 to 30.00 MΩ |
Resolution |
|
0.01, 0.1, 1, automatic |
Accuracy |
|
±1% F.S. |
Conductivity Ash |
|
|
Range |
|
0.00 to 100% |
Resolution |
|
0.01, 0.1, 1, automatic |
Accuracy |
|
±1% F.S. |
Measurement Modes |
|
ICUMSA GS1 / GS2 |
Temperature |
|
|
Range |
|
0 to 105°C / 32 to 221°F |
Resolution |
|
0.1°C/°F |
Accuracy |
|
±0.5°C / ±0.9°F |
Calibration |
|
1 point |
Calibration Range |
|
Reading ±10°C/°F |
Other Specifications |
|
|
Temperature Compensation |
|
0 to 100°C / 32 to 212°F, manual or automatic |
Temperature Coefficient |
|
Linear (0.0 to 10.0%/°C) / Non-linear / Pure water |
Reference Temperature |
|
20 / 25°C |
Cell Constant |
|
2-pole electrodes (K=0.1 / 1 / 10) or 4-pole electrode |
Stability Criteria |
|
Standard / High-accuracy |
Measurement Modes |
|
Continuous / Auto-read measurement endpoint |
Timed Interval Readings |
|
10 / 30 / 60 seconds, 10 / 30 minutes or off |
Calibration Due Alarm |
|
1 to 31 days or off |
High/Low Limit Alarm |
|
Selectable |
Password Protection |
|
4 digits |
Memory |
|
Stores up to 1000 data sets |
Output |
|
USB communication interface |
Connector |
|
6-pin mini-DIN, 3.5 mm jack socket |
Display |
|
7 inch TFT LCD |
Power Supply |
|
12V DC power adapter |
Environmental Conditions |
|
0 to 50°C / 32 to 122°F, relative humidity < 80% |
Dimensions |
|
240 × 220 × 80 mm |
Weight |
|